[ pdf ] Calibration and Standards in Flow Measurement

Calibration and Standards in Flow Measurement Download
259
times
Topic under  Flow Measurement
Source: eu.wiley.com 
File size: 157.76 KB
File type: pdf
Last download on: Fri Jul 14, 2017 08:38:41 AM
Short Desciption:
1 General Principles 1 2 Gravimetric Calibration of Liquid Flowmeters 2 3 Volumetric Calibration of Liquid Flowmeters 3 4 Calibration of Gas Flowmeters 3 5 Mixed or Multiphase Flowmeters 4 6 In Situ or Field Calibration 5 References 5

Summary:
1 GENERAL PRINCIPLES Calibration is dened as follows: The set of operations that establish, under specied conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system and the corresponding values realized by standards. It is important to recognize at the outset the denition of a calibration and to note that the comparison applies only to the conditions at the time of the calibration. The purpose of calibration is to increase the condence in the reading obtained from the owmeter in service. Standards for ow measurement are based on a comparison of the quantity of uid passed, or passing, through the owmeter with the quantity measured by the standard. Standards can be based on the measurement of mass or volume. The required mass or volume quantity can be calculated from the measured quantity from a knowledge of the uid density at the test owmeter. Standards may be static or dynamic, and this choice is made on the basis of the output and end use of the owmeter. Some owmeters are used to measure quantity and have a fast response time; others are designed to measure ow rate and have a slow response time. Calibration of a owmeter should cover a signicant ow-rate range for the owmeter and establish a performance across that range.
Bookmark or share this info on Google+ and leave comment at below :

Bookmark and Share

People who downloaded this also viewed in this sites:

ORIFICE METERING FUNDAMENTALS
THEORY OF ORIFICE MEASUREMENT The law of conservation of energy applied to a fluid under the condition of steady, uniform flow requires the...

Flow Orifice Sizing
Beta Ratio Limits Beta ratio β = d D = Bore P ipe ID Change pipe size or pressure drop to stay within beta ratio range for flow...

Coriolis Mass Fllow Meters for Naturall Gas Measurement
Theory of Operation Density Operatiion Densiity & Piiickoffff Siiignalll...

    Leave comment :
    "Calibration and Standards in Flow Measurement"

    Name*

    Comment


    Related Free Files

    STANDARD HANDBOOK OF PETROLEUM AND NATURAL... - Download: 618 times
    Flow Measurement... - Download: 644 times
    DESIGN AND ANALYSIS OF CORIOLIS MASS... - Download: 61 times
    Flow Orifice Sizing... - Download: 80 times
    CORIOLIS MASS FLOW DENSITY AND TEMPERATURE... - Download: 56 times
    The orifice meter and gas measurement... - Download: 863 times
    ORIFICE FITTINGS AND METER TUBES... - Download: 198 times
    Flow Measurement... - Download: 574 times
    HANDBOOK OF MULTIPHASE FLOW METERING... - Download: 436 times
    STANDARD HANDBOOK OF PETROLEUM AND NATURAL... - Download: 323 times


    eXTReMe Tracker