Home > Pipe-Fittings > Piping Systems


[ pdf ] Cathodic Protection

Cathodic Protection Download
1252
times
Topic under  Piping Systems
Source: artikel-software.com 
File size: 577.75 KB
File type: pdf
Last download on: Mon Dec 11, 2017 11:31:14 PM
Short Desciption:
UFC 3-570-02A. 01 March 2005. UNIFIED FACILITIES CRITERIA (UFC). CATHODIC PROTECTION. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED

Summary:
i LIST OF FIGURES Figure Page 1-1 Corrosion of a pipeline due to localized anode and cathode sites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-2. Galvanic and impressed current systems for cathodic protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 2-1. Design sequence for cathodic protection systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 A-1. Wenner four-pin method for measuring resistivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 A-2. Soil box for soil resistivity measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 B-1. Current requirement test on pipelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 C-1. Galvanic anode cathodic protection for hydrant refueling system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1 C-2. Galvanic anode cathodic protection for underground steel storage tank . . . . . . . . . . . . . . . . . . . . . . . . . C-4 C-5. Layout of gas piping in residential district . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-5 D-l. Cathodic protection system for gas main . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-l D-2. Impressed current cathodic protection for heating conduit system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-4 D-3. Cathodic protection for black iron hot water storage tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-7 D-4. Fringe factor for stub anodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-9 D-5. Dimensions for an elevated steel water tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-10 D-6. Cathodic protection for tanks using rigid-mounted button-type anodes and platinized titanium wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-12 D-7. Segmented elevated tank for area calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-13 D-8. Anode spacing for elevated steel water tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-15 D-9. Anode suspension arrangement for elevated steel water tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-17 D-10. Equivalent diameter factor for anodes in a circule in water tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-18 ____________ This manual supersedes Sections VII, VIII, and IX of TM 5-811-4, 1 August 1962. TM 5-811-7 LIST OF FIGURES (CONT’d) Paragraph Page D-l 1. Elevated steel water tank showing rectifier and anode arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-24 D-12. Hand hole and anode suspension detail for elevated water tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-25 D-13. Riser anode suspension detail for elevated water tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-25 E-1. Ceramic anode specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-l F-1. Structure-to-soil potential versus distance from foreign structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1 F-2. Cathodic interference testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-2 LIST OF TABLES Table Page 2-1. Corrosivity of soils on steel based on soil resistivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-2. Typical current density requirements for cathodic protection of uncoated steel . . . . . . . . . . . . . . . . . . . 2-2 2-3. Weights and dimensions of selected high-potential magnesium-alloy anodes . . . . . . . . . . . . . . . . . . . . . 2-4 2-4. Weights and dimensions of selected circular high-silicon chromium-bearing cast iron anodes . . . . . . . 2-6 2-5. Shape functions (K) for impressed current cathodic protection anodes where L is the effective anode length and d is the anode/backfill diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 2-6 Anode paralleling factors (P) for various numbers of anodes (N) installed in parallel . . . . . . . . . . . . . . 2-6 C-1 Outside area of liquid fuel pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2 C-2. Requirements for anode spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-5 C-3. Dimensions for finding outside area of pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-6 C-4. Galvanic anode size factor If) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-7 C-5. Structure potential factor (y) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-7 C-6. Dimensions for finding anode division . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8 D-1. Dimensions for finding steam conduit area: heat distribution system . . . . . . . . . . . . . . . . . . . . . . . . . . . D-5 D-2. Dimensions for finding condensate return conduit area: heat distribution system . . . . . . . . . . . . . . . . . . D-5 D-3. Conduit area: heat distribution system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-6 D-4. Anode division: heat distribution system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-7 D-5. Technical data: commonly used HSCBCI anodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
Bookmark or share this info on Google+ and leave comment at below :

Bookmark and Share

People who downloaded this also viewed in this sites:

Flanged Rating Tickness Tables
Our range of Flanges includes 600lbs Flanges. Normal pipe size. Outside .... class flange dimensions, 600 ansi pressure rating, 600 lb flange...

Liquid Process Piping
Liquid Process Piping Handbook...

Welding & Fabrication
ENG T 101 (or MATH 099 or higher)* Introduction to Graphics and Measurements ... Introduction to Geographic Information Systems. WELD 212....

    Leave comment :
    "Cathodic Protection"

    Name*

    Comment


    Related Free Files

    Welding & Fabrication... - Download: 1995 times
    Liquid Process Piping... - Download: 2451 times
    Piping Systems and Pipeline... - Download: 5058 times
    Flanged Rating Tickness Tables... - Download: 978 times
    Thermoplastic Industrial Piping Systems... - Download: 747 times


    eXTReMe Tracker